RFellow
Local processing
S-PARAMETER ANALYSIS · LOCAL BY DEFAULT

Inspect, combine and qualify Touchstone data.

Open RF measurements directly in your browser. Plot S-parameters, use Smith and group-delay views, cascade 2-port networks, place stable named markers and check engineering limits without uploading the files.

No accountNo RF file uploadCommercial engineering use allowed
RF WORKSPACE

Touchstone viewer

Active DUT: No active DUT

R2.13 engineering preview
Mouse
Markers
1–9 select marker
Full span
MEASURESelect a marker, then click the plotΔ1 · place M1 and M2
Measurements
RFELLOW · ANALYZER

Markers & measurements

Choose a marker, search a trace, or compare two points.

?
01

Markers

Select a point to measure or change its frequency.

CURSORSAdd a cursor to compare traces here.
Click place the active marker, or move a selected cursor when Move is enabledDrag live panWheel zoom at cursorDelta measurements are separate from markers and may be added independentlyBox zoom choose mode then drag a bandReset view restores the shared frequency span; Full range shows all file frequenciesLocked markers cannot move or clearGroup delay is estimated from discrete phase samples; sparse sweeps can alias
Cascade networksCombine two .s2p files in physical signal-path orderExpand
FULL TWO-PORT NETWORKStage 1 feeds Stage 2Select input-side and output-side networks in the order they are physically connected.
How cascading works →

Load at least two 2-port files to combine networks.

What RFellow calculatesFull two-port cascade including interstage reflections—not just S21 dB addition. The files must use the same real Z₀ and share a frequency span. Result is a new derived dataset; source files stay unchanged.
LIMIT CHECK

Engineering requirements

Create several independent requirements such as insertion loss ≤ 2 dB and input return loss ≥ 15 dB. PASS requires every configured requirement to be evaluated and met at the available sampled frequencies. INCOMPLETE means a required parameter or sampled band is unavailable; FAIL means a measured sample exceeded a limit. A sparse sweep cannot prove compliance between measurement points.

Insertion loss is −20·log₁₀|S21|, so a smaller positive number is better.
RFellow TOOL REFERENCE

Find the meaning behind each RFellow control.

Fifteen focused topics explain Touchstone files, S-parameters, loss, VSWR, phase, group delay, Smith charts, markers, requirements and cascade—with the equations and current tool limits. Introductory RF Academy lessons are a separate future project.

Open Tool Reference →
PRIVACY

Your RF files stay on your device.

See exactly what RFellow processes locally, what this preview does not transmit, and what would require a policy update later.

Read privacy details →
ENGINEERING-USE NOTICE

Analysis aid, not a certification authority.

See the measurement assumptions, reference-plane responsibilities, uncertainty limitations and commercial-use engineering notice.

Read engineering notice →
THE RF COMMUNITY

Tools, learning and professional connections.

Explore carefully reviewed RF training and partner resources, share RFellow, or tell us what to improve.